For the bed temperature measuring point of fluidized bed, the temperature sensor is required to be wear-resistant, high-temperature resistant and corrosion-resistant. It is recommended to use high-temperature wear-resistant alloy casing pipe to resist wear.
 
 
Technical parameters of fluidized bed temperature sensor
——————————————————————————————————————————————————————
Graduation: K, N
Temperature measurement range: 0~1,200℃
Nominal pressure: ≤ 9.8MPa
Total length/insertion depth: 480/230, 680/430, 880/630
External protective pipe: High-temperature wear-resistant alloy (CoCr)
Process connection: Fixed thread, fixed flange
 
 
Recommended parameters for bed temperature sensor of fluidized bed
——————————————————————————————————————————————————————
Graduation: K
Temperature measurement range: 0~1,000℃
Number of pairs: Double pieces
Diameter of sheathed wire: Φ5 or Φ6
Protective pipe: High-temperature wear-resistant alloy (CoCr)
Process connection: Fixed thread
 
 
At the temperature measuring point of the fluidized bed, the temperature casing pipe is severely worn under the erosion of high flow velocity pulverized coal particles. In the high temperature corrosion environment, its service life often cannot meet the requirements of stable operation of the unit. Therefore, the wear-resistant casing pipe shall be wear-resistant, corrosion-resistant and high-temperature resistant.
Recommended temperature sensor model: TCK-S02/CoCr-Φ-U-L/K222C06/SY
 
 